Cost effective solution for RS-232 / RS-422 / RS-485 to Ethernet application
PLANET ICS-10x series Media Converter / Device Server can convert Serial RS-232 / RS-422 / RS-485 communication interface over Fast Ethernet networking. There are RJ-45 and SC type connectors and single-mode / multi-mode media for customers needs. Ethernet signal allows the two types of segments to connect easily, efficiently and inexpensively. The ICS-10x converter can be used as a stand-alone unit or as a slide-in module to the PLANET Media Converter Chassis (MC-700 and MC-1500). It greatly saves time and expense for users and SI without the need of replacing the existing Serial equipment and software system.
Extend distance
The ICS-10x extends the distance of deploying Serial equipments and hosts. The selectable fiber-Optic wires on the basis of distance are provided. Therefore, this product will perfectly satisfy the diverse demands while providing reliable and efficient network solutions based on the distance and budgets of installation.

Remote Manageable
The ICS-10x enables the Serial equipment be connected via IP-based transmission. It also makes them be able to connect to a TCP / IP networking immediately. The ICS-10x Web Smart media converter provides management through Web Interface. It supports Application mode, Serial operation mode alarm connection and IP address, etc. It helps the network administrators to reduce the amount of valuable time spending on detecting and locating network problems, otherwise it requires visual inspection of cabling and equipment. For large networking environment, multiple connection options are available with the ICS-10x as well.
Ordering Information |
ICS-100 |
RS-232/422/485 over Fast Ethernet Media Converter (RJ-45) – 100m |
ICS-102* |
RS-232/422/485 over Fast Ethernet Media Converter (SC, MM) – 2km |
ICS-102S15* |
RS-232/422/485 over Fast Ethernet Media Converter (SC, SM) – 15km |
ICS-105A |
RS-232/422/485 over Fast Ethernet Media Converter (SFP) – Vary on module |
(*) |
Upon by request |
Accessories |
RKE-DIN |
DIN-Rail Mounting Kit |
Access Control System – traditional installation
Most of the enterprises and governments use access control plate and Mifare or RFID to authorize entrance identity. With traditional deployment, access control machines use the RS-232 or RS-485 serial interface and cables connecting to login server. With connection with the ICS-10x Serial over Fast Ethernet Converter, the access control machine is able to be extended over longer distances via fiber optical interface. The distance can be up to 20km in a local range. The ICS-10x can also be linked to a XDSL router to get the internet access capability; then the access control can be set and monitored over the internet.

Process Control
The PLC (Programmable Logical Control) is required to monitor, configure and manage the Robot conveyer including other machines in the manufacturing process. The ICS-10x can be set to TCP Server mode and connect with the PLC. Therefore, the administrator can remotely configure and set command settings through Fast Ethernet intranet to control the PLC, the administrators and workstations. There is no need for the administrators to be always by the I/O machine.

RTU Data Collect – UDP Mode
The RTU (Remote Terminal Unit) may be applied to collect and monitor the data of waves, signal and power utilization. Connecting the RTU with the ICS-10x in UDP mode, the data can be sent over Fast Ethernet to local server or over Internet to remote server automatically.
Surveillance Motion Control – Pair Connection Mode
Using pair connection along with the fiber optical patch cord, the ICS-10x extends the remote central surveillance monitoring with the control keyboard/joystick via RS-232 / RS-422 / RS-485 interfaces.

Serial Interface
• One RS-232 / 422 / 485 port to one 100Base-FX Media Converter
• Cost effective solution for RS-232 to Ethernet application
• Supports RS-232, 4-wire RS-422 or 2/4-wire RS485 operation
• Asynchronous serial data rates up to 921600bps
Ethernet Interface
• Complies with IEEE 802.3u 100Base-FX standard
• Choice of fiber-connector from SC / LC, multi-mode / single-mode fiber
Smart Functions
• Standard TCP / IP interface and versatile operation modes
• Software Protocol Supported: ARP, ICMP,TCP / IP, UDP, HTTP server, DHCP client, Telnet server/client
• Built-in IP-Based Web interface for remote management
• Serial Operation mode selected via Web management
• Pair Connection mode for connecting two serial devices over a network
• PLANET Smart Discovery utility automatically finds PLANET devices on the network
• Firmware upgrade via HTTP protocol
Hardware
• Compact size for easy Installation
-Standalone - Wall mountable or DIN-Rail mounting (Optional accessory)
-Co-work with PLANET MC family Media Chassis (MC-700 / MC-1500 / MC-1500R / MC-1500R48)
• LED indicators for easy network diagnose
• Reset Button at the front panel for reset to factory default
Specification
Serial Port |
Interface |
RS-232 / RS-422 / RS-485 |
Connector |
3-in-1 DB9 |
Baud rate (Data Rate) |
300bps to 921600bps |
Data Bits |
5,6,7,8 |
Stop Bit |
1,2 |
Flow Control |
None, RTS / CTS, Xon / Xoff |
Signals |
RS-232: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS-422: Tx+, Tx-, Rx+, Rx-
RS-485(2-wire): Data+, Data-
RS-485(4-wire): Tx+, Tx-, Rx+, Rx- |
Fast Ethernet Port |
Standard |
100Base-FX |
Connector |
SC Interface : ICS-102 / ICS-102S15
LC Interface : ICS-105A |
Mode |
ICS-102: Multi-Mode
ICS-102S15: Single Mode
ICS-105A : Vary on SFP Module |
Distance |
ICS-102: 2km
ICS-102S15: 15km
ICS-105A : Vary on SFP Module |
Optical Wavelength |
ICS-102: 1300nm
ICS-102S15: 1310nm
ICS-105A : Vary on SFP Module |
Cable |
ICS-102: 50/125μm or 62.5/125μm multi-mode fiber cable
ICS-102S15: 9/125μm single-mode cable
ICS-105A : Vary on SFP Module |
Protection |
Built-in 1.5KV magnetic isolation |
Hardware |
LED Indicators |
System: Power
TP or Fiber Port: Link / Active
Serial Port: Serial port mode, RS-232, RS-422 or RS-485 |
Management |
Web Management
PLANET Smart Discovery Utility
VCOM |
Operation Mode |
Virtual COM Port
TCP Server
TCP Client
UDP Client
Pair Connection |
Dimension (W x D x H) |
97 x 70 x 26 mm |
Weight |
200g |
Power Supply |
External Power Adaptor 5V DC / 2A max. |
Power Consumption |
5.5 Watts (max) |
Mechanical |
Metal |
Environment |
Operating Temperature: 0~50 Degree C
Storage Temperature: -10~70 Degree C
Operating Humidity: 10%~90% RH
Storage Humidity: 5%~90% RH |
Emissions |
FCC Class A, CE Certification |
Standards |
• IEEE 802.3 10Base-T,
• IEEE 802.3u 100Base-TX / 100Base-FX
• EIA / TIA RS-232 / 422 / 485 |
Regulatory Approval |
RoHS |
Compatible Media Converter Chassis |
MC-700 / 1500 |
Note |
Reset Button at the rear panel for reset to factory default |
|